| Models |
| F2: 2U 8bay SATA/SAS; U320 SCSI or 4Gb FC host ports |
| F3: 2U 12bay SATA/SAS; U320 SCSI, 4Gb FC, or iSCSI host ports |
| F4: 3U 16bay SATA/SAS; U320 SCSI, 4Gb FC, or iSCSI host ports |
| F5: 4U 24bay SATA/SAS; U320 SCSI or 4Gb FC host ports |
| F6: 3U-19U 16-96bay SATA/SAS/FC; 4Gb FC host ports |
| Supported Hot-swap Drives |
| 250, 400, 500, 750GB 1TB 7200rpm SATA 3Gb/s Raid Edition |
| 150GB 10000rpm SATA 1.5Gb/s |
| 73, 146GB 15000rpm SAS |
| RAID Controllers |
| F2 & F3: Single removable |
| F4 & F5: Single or Dual-Active Removable |
| F6: Dual-Active Removable |
| Controller Cache |
| F2 & F3: 256MB DDR |
| F4 & F5: 512MB-1GB per controller |
| F6: 512MB-1GB per controller |
| Battery Backed Cache Support |
| F4, F5, F6 |
| RAID Levels & LUN Support |
| 0, 1, 3, 5, 6, 10, 30, 50, 60 |
| 1024 LUNs |
| Variable Stripe Sizes |
| Host Interface Options |
| F2: 2x U320 SCSI, 2x 4Gb FC, 3Gb/s SAS |
| F3: 2x U320 SCSI, 2x 4Gb FC, 3Gb/s SAS, 4x 1Gb Ethernet |
| F4: 2x U320 SCSI, 2-8 4Gb FC, 3Gb/s SAS, 2x 1Gb |
| F5: 2x U320 SCSI, 4x 2Gb FC |
| F6: 2-8 2Gb FC |
| System Management & User Interfaces |
| Global and Dedicated Hot Spare drives with auto rebuild |
| Local/Remote embedded GUI via IP (10/100 ethernet) |
| SNMP 2.0 MIBs |
| Telnet (IP or serial access) |
| Front panel LCD with activity/error LEDs |
| Power & Cooling |
| Redundant + Hot-swap ( all models ) |
| 100-240VAC |